3-Phase Inverter Motor Drive Analysis

5 Series/6 Series B MSO Option 5-IMDA/6-IMDA Application Datasheet

Lire en ligne :

Measurements and analysis on three-phase power systems are inherently more complex than on single-phase systems. Although oscilloscopes can capture voltage and current waveforms with high sample rates, further calculations are required to produce key power measurements from the data. The oscilloscope based three-phase solution allows to capture three-phase voltage and current waveforms with higher sample rates, longer record lengths using the HiRes acquisition mode that goes up to 16-bits and with the support of automated measurements produce key power test results. The Power converters based on Pulse Width Modulation (PWM), such as variable-frequency motor drives can complicate measurements since it is very important to extract precise zero crossings for the PWM signals, thus making an oscilloscope a recommended test tool for validation and troubleshooting for motor designers. Special software, designed to automate power analysis on inverters, motors, and drives, greatly simplifies important three-phase power measurements on PWM systems and can help engineers get faster insights into their designs. The Inverter Motor Drive Analysis (IMDA) solution from Tektronix helps engineers design better and more efficient three-phase motor drive systems, taking full advantage of the advanced user interface, six or eight analog input channels, and ‘High Res’ mode (16 bits) on the 5 Series/6 Series B MSO. The IMDA solution provides fast, accurate, and repeatable results for electrical measurements on industrial motors and drive systems for AC induction motors, permanent magnet synchronous motors (PMSM), and brushless DC (BLDC) motors. It can be configured to measure DC to three-phase AC converters, such as those used in the electric vehicles.

Key features and specifications

  • Accurately analyze three-phase PWM signals used to drive AC induction, BLDC, and PMSM motors.
  • Unique oscilloscope based phasor diagrams indicate VRMS, IRMS, VMAG, IMAG, and phase relationships at a glance for the configured wiring pairs.
  • Debug motor drive designs by viewing the drive input/output voltage and current signals in the time domain simultaneously with the phasor diagram.
  • Three-phase Autoset feature configures the oscilloscope for optimal horizontal, vertical, trigger, and acquisition parameters for acquiring three-phase signals.
  • Measures three-phase harmonics per the IEC-61000-3-2, IEEE-519, or custom limits.
  • Measures the system efficiency based on the selected wiring configurations.
  • Quickly add and configure measurements through the intuitive drag and drop interface on the 5 Series / 6 Series B MSO.
  • Analyze Inverter and Automotive three-phase designs for DC input and AC output wiring configuration.
  • Displays the PWM filtered edge qualifier waveform during analysis.
  • Displays the test results per Record, or per Cycle mode during analysis for specific measurements.
  • Supports Time trend and Acquisition trend plots for specific measurements.
  • Supports mathematical conversion of Line-Line to Line-Neutral for specific wiring.
  • Supports DQ0 measurements with the phasor plot.
  • Supports mechanical measurements using Hall sensor signals.

Measurement overview

Three-phase power converters such as variable frequency drives require a range of measurements during the design process. The Inverters, Motors, and Drives Analysis package for the 5 Series/6 Series B MSO automates key electrical measurements which are grouped into the Electrical Analysis group. The measurements can be configured to measure the Input or Output wiring configuration.

5_IMDA_48W 61649 3
IMDA measurements under Electrical Analysis group

The measurements can be set to measure 1V1I (1-Phase-2-Wire), 2V2I (1-Phase-3-Wire), 2V2I (3-Phase-3-Wire), 1V1I (1-Phase 2-Wire DC) or 3V3I (3-Phase-3-Wire), and 3P4W (3-Phase-4-Wire) to support various supply and motor configurations. Measurements can be performed line-to-line or line-to-neutral, to support delta and wye or star configurations.

5_IMDA_48W 61649 3
Configuring the measurement for Input wiring configuration

Harmonics

Power waveforms are rarely textbook sinusoids. Harmonics measurements break down non-sinusoidal voltage or current waveforms into their sinusoidal components, indicating the frequency and amplitude for each component.

Harmonics analysis can be performed up to 200th harmonic order. The maximum harmonic order can be set to suit your needs by specifying the range in the measurement configuration. THD-F, THD-R and fundamental values are measured for each phase. Measurements can be evaluated against the IEEE-519 or IEC 61000-3-2 standard, or custom limits. Test results can be recorded in a detailed report indicating pass/fail status.

5_IMDA_48W 61649 3
Compare harmonics measurements against industry standards or custom limits

5_IMDA_48W 61649 3
A sample harmonics plot indicates passing harmonics test results. Each set of bars contains results for Phase A, B, and C for easy correlation.

The Harmonics plot shows the test results for all three phases grouped together so user can correlate the test results between the phases. The plot also shows the test results visually. The harmonics bars are highlighted in green color during a pass condition, and highlight to red color when it exceeds the test limits. This gives a quick insight when debugging for harmonics design.

Power quality

This measurement provides critical three-phase power sub-measurements including: frequency and RMS magnitudes of voltage and current, crest factors of voltage and current, PWM frequency, and phase angle for each phase. It also displays the sum of true power, sum of reactive power, sum of apparent power components.

Additionally, in the Line-Neutral configuration, this measurement displays True Power, Reactive Power, and Apparent Power components of all the three-phases.

Voltage and current vectors can be displayed on a phasor diagram so you can quickly judge phase shift for each phase and the balance among phases. Each vector is represented by an RMS value and phase is computed using the Discrete Fourier Transform (DFT) method.

5_IMDA_48W 61649 3
Easily configure the settings to get insight into the power quality
5_IMDA_48W 61649 3
Method to compute power quality

The Power quality measurement can be configured to provide critical three-phase power measurements on the output side, including: frequency and RMS magnitudes of voltage and current, crest factors of voltage and current, PWM frequency, true power, reactive power, apparent power, power factor, and phase angle for each phase.

5_IMDA_48W 61649 3
Easily configure the voltage and current inputs on the Power Quality measurement to display phasor diagrams

5_IMDA_48W 61649 3
Unique oscilloscope based phasor diagram feature provides the relation between the voltage and current vectors

Efficiency

Efficiency measures the ratio of the output power to input power. The IMDA solution supports efficiency of three-phase AC and Inverter configurations. By using the 2V2I method, three-phase efficiency can be measured using eight oscilloscope channels (2 voltage and 2 current sources on the input side and 2 voltage and 2 current sources on the output side). The solution calculates efficiency at each phase (for 3V3I configuration) and the total (average) efficiency of the system based on the different input and output wiring combinations.

5_IMDA_48W 61649 3
Configure wiring and filters to perform efficiency measurements for an Industrial motor
5_IMDA_48W 61649 3
Configure wiring and filters to perform efficiency measurements for a DC-AC topology most suitable for inverter testing

5_IMDA_48W 61649 3
Get complete insight into the overall system efficiency

Ripple analysis

Ripple is defined as the residual or unwanted AC voltage on a constant DC component. It is typically measured on the DC bus. This measurement helps to understand how efficiently the signal is getting converted from AC-DC on the input side, and the impact of unwanted components on the PWM signal on the output side.

5_IMDA_48W 61649 3
Ripple analysis configuration can be set to look into line and switching ripple
5_IMDA_48W 61649 3
Ripple measurement being carried out on the DC-input signals when testing an Inverter

Direct Quadrature Zero (DQ0) analysis

The behavior of three-phase AC machines can be described by rotating voltage and current equations as below.

5_IMDA_48W 61649 3

Where,

A, B, and C are three phase AC signals.

'Vg' is the corresponding gain.

'w(t)' is the 2pi×f×t.

The voltages (V) and currents (I) at the AC interface are usually separated, typically 120 degrees out of phase. These V and I components are time-varying, which means there is no representation of a steady-state operation point.

Generally, AC signals are real-world signals, but converting them to DC helps get an abstract representation of the direct quadrature transform. The DQ0 assists in emulating the controller. This information helps to understand more about what the controller is doing and allows to tune the controller design.

The DQ0 transformations typically rotate the reference frames of AC waveforms to convert them to DC signals. This allows simplified calculations on the DC signals before performing the inverse transform to recover the actual three-phase AC results.

To measure and monitor the control system’s output, the designers depend on FPGA’s and ASIC-based hardware to handle sensor data to get the DQ0 information and then check the control information through multiple iterations. This solution involves a complex and time taking process.

It is practically challenging to measure or probe the D-Q-0 signals. A typical solution provides an external stimulus to the controller to replicate the controller input signals and the Analog-Digital Controller (ADC) outputs as the DQ0 signals.

To address this challenge, users depend on the software application DQ0 solution to understand the complex dynamic phenomena in power control systems.

The IMDA solution features DQ0 transformation, which rotates the reference frames of the three phase waveforms, so they become DC signals. Calculations can be simplified on these DC quantities before inverting them and getting to the actual three-phase AC results. A basic control scheme is shown in the following figure.

5_IMDA_48W 61649 3
Typical connection setup and probing points for doing DQ0 measurements

Tektronix offers a patented on-scope measurement called DQ0 under the electrical analysis measurement category as an added option using Clarke’s and Park’s transformation matrix. The DQ0 feature is available as an option 5-IMDA-DQ0/6-IMDA-DQ0 on the 5 series and 6 series MSO.

The DQ0 method calculates the angle (θ) as 2*pi*f*t and extrapolates the reference frame based on where we expect time-varying signals to be. The DQ0 frame (phasor diagram) rotates with the right speed and frequency and not necessarily in phase with the rotor, which helps to understand the instantaneous state of the motor.

This measurement is supported in the 3V3I configuration, takes the three-phase voltage or current signals from the motor as inputs, and converts them into D-Q-0 coefficients acting as a powerful debugging tool for the motor designers to tune their PWM controller circuit designs.

The measurement computes real-time DQ0 transformation by converting the 3-phase drive output voltage or current waveforms. The transform matrix converts time-varying AC signals into time-invariant DC components. This helps to reproduce the control system's understanding of instantaneous motor torque and speed. The use of the DQ0 transformation allows motor designers to correlate the performance of the 3Phase power section to control system of the hardware algorithms and design. The overlapped DQ0 and 3-phase ABC vectors act as a good debug feature for designers to observe simultaneously both vector axis on the same plot.

There are different outputs of this measurement such as scalar values with the magnitude of D and Q, RMS values with statistics, derived math waveforms, and a phasor diagram. Math waveform provides the DC transformed waveform. This provides the different views of the control system outputs in a single view.

By observing the DQ0 results, some important inferences can be drawn, such as variations indicating to RMS ripple, peak to peak values, and higher-order harmonics. These parameters directly relate to understanding the operation of the algorithms in the control systems. Without this information, it would be difficult to understand the performance of the motor control systems.

5_IMDA_48W 61649 3
DQ0 measurements running on the 5 Series MSO. They are represented on the phasor diagram as VQ (green), VD(orange), and VZ (white) vectors and their scalar values are available in the results badge on the right. The DQ0 waveforms are shown as Math M12- filtered waveform (Green), M13 - Direct (Orange), M14 – Quadrature (Purple) and M15 – Zero (Red).

Dynamic measurements using trend analysis

A common requirement in motor drive analysis is an ability to look at the motor response over longer test times, records, and an extended number of acquisitions to monitor the DUT behavior over varying load conditions. This dynamic measurement helps to understand optimal designs and interdependency between different parameters like voltage, current, power, frequency, and their variance based on the load conditions. You can manually zoom and get the specific region of interest to look at test results at the particular region of the waveform.

IMDA solution offers two unique trend plots on the power quality measurement to support such requirements:

  • Time trend plot
  • Acq trend plot

Each plot has its advantages and can be used to plot the supported sub-measurements under power quality measurement. The time trend plot shows the measured value per cycle, or for an acquired waveform (a record), while the acq trend plot shows a mean of the measured value per record, over each of the acquisitions. The acquisition count can be set during the test configuration. This allows you to capture long records of data to perform deep record analysis and understand the dynamic behaviors of the motor response. The plots can be saved as a CSV file for post-processing.

5_IMDA_48W 61649 3
Time trends enable you to graphically analyze power measurements within one acquisition record. Acquisition trends can plot power measurements over many acquisitions for longer-term testing.

5_IMDA_48W 61649 3
This example shows acquisition trend plots of mean power measurements for 100 acquisitions, including - Vrms, Irms, phase difference, sum of true power, apparent power, and reactive power.

5_IMDA_48W 61649 3
Add and configure the Time Trend plot on different sub-measurements of Power Quality measurement. The image shows two time-tend plots monitoring Vrms and Frequency parameters.

Mechanical analysis

IMDA mechanical analysis group (Option IMDA-MECH) supports hall sensor output signals to calculate speed, acceleration, and direction information. The acceleration results are reported as part of the speed measurement. The measurement requires the number of pole pairs and corresponding gear ratio to measure key motor parameters. The direction measurement expects a sequence of hall sensor rising edges to be configured before operation and validates them during the operation.

TPP1000 passive probes or high voltage differential THDP0200/100 probes can be used to capture the sensor outputs depending on the motor output power and noise levels. Digital channels with TLP logic probes are recommended for use instead of analog because of lesser noise and can help to conserve analog channels for other tests operations and use single flex channel for the measurement.

5_IMDA_48W 61649 3
IMDA mechanical analysis supports speed (with acceleration) and direction measurements

Speed measurement

Hall sensor signal transition as shown in the following figure.

5_IMDA_48W 61649 3
Speed measurement computation using three hall sensor transitions

Speed is defined by the following equation,

5_IMDA_48W 61649 3

Where,

Difference between TSP and TST is defined by the number of pole pairs.

TST is the start if the electrical pulse

TSP is the stop if the electrical pulse

60 is the RPM (revolitions per minute)

G is the gear ratio.

Acceleration

Acceleration is rate of change of speed per unit time. It is defined as

5_IMDA_48W 61649 3

Speed and direction support following plots:

  • Histogram
  • Time Trend
  • ACQ Trend

Importance of speed ACQ trend plots

The ACQ trend along with the histogram plot shows jitter on motor speed, which otherwise requires dedicated instrument like a flutter meter to measure. This jitter information (variations in edge timing) measures the motor-speed consistency.

5_IMDA_48W 61649 3
ACQ trend plot displaying Jitter on the motor speed (left) along with a histogram plot (right) that indicates the speed distribution

Motor start-up profile

Motor designers are interested to investigate the motor startup profile during the design stage. The time trend gives the instantaneous speed information of a motor which otherwise is hard to measure.

In the following Time trend plot showing startup sequence of a motor image, where the start-up time taken by the motor is 2.3s from OFF to a ON state. Similarly, one can perform ON to OFF state and gain insights into the de-acceleration process as shown in the figure Time trend plot showing deceleration of a motor into a stop state image.

5_IMDA_48W 61649 3
Time trend plot displaying startup sequence of a motor
5_IMDA_48W 61649 3
Time trend plot displaying deceleration of a motor into a stop state

Direction

Some applications like drills, washing machines, and electric pumps require motor to operate and change directions rapidly. The direction measurement helps with this analysis. The order of rising edges or falling edges of hall sensor output determines the direction of rotation. The direction measurement needs all three hall signals. They are available as configurable parameters for the direction measurement and are validated during the motor operation. Generally, a A-B-C sequence is interpreted as clockwise (CW) and a A-C-B sequence is interpreted as counter-clockwise (CCW).

For example, if the first rising edge is from HALL A and a rising edge of HALL B exists at 120 degrees, then the rotor rotation sequence is A-B-C. Else, if the second rising edge of HALL C occurs at 120 degrees, then the sequence is A-C-B.

5_IMDA_48W 61649 3
Direction information interpreted from the Hall sensor outputs
5_IMDA_48W 61649 3
Direction information captured on the scope shows a HALL A,B,C rising edge sequence (clockwise rotation)

Here is the formula used to compute the direction information.

Order (Clockwise) = (A-B-C)

Order (Counter-clockwise) = (A-C-B)

Where Order function checks for the sequence of rising edges on all three hall sensor signals.

Direction can be displayed as an ACQ trend plot to give a visual indication on an exact timestamp when the motor reversed the direction helping during the debug. This is shown as a sample plot in the following figure.

5_IMDA_48W 61649 3
The ACQ trend plot shows +1 and -1 based on CW and CCW motor rotation.

Report generation

The IMDA software simplifies data collection, archiving, documentation of your design, and development process. It supports the report generation in MHT or PDF formats with pass/fail results for easy analysis.

5_IMDA_48W 61649 3
A sample IMDA test report file with summary, details, and corresponding images

Specifications

Wiring configuration
1V1I (1-Phase-2Wire), 2V2I (1 Phase-3-Wire), 2V2I (3-Phase-3-Wire), 2V2I (DC In-AC Out), 3V3I (DC In-AC Out) or 3V3I (3-Phase-3Wire), and 3P4W (3-Phase-4Wire)
L-L to L-N conversion
Applicable for 3 Phase-3 Wire (3V3I)1
Electrical analysis
Power quality, Harmonics2, Ripple, DQ03, Efficiency4
Mechanical analysis
Speed, Acceleration, and Direction
Three-phase autoset
For all measurements
Plots
Time Trend plot, ACQ trend plot, Phasor diagram, harmonics bar graph 5, DQ0 plot, and Histogram plot (speed distribution)
Report
MHT and PDF format, Data export to CSV format
Degauss/Deskew (static)
Automatic detection of probes, Auto Zero. User can deskew voltage and current probes, degauss the current probe from the menus for each channel
Source support
Live analog signals, reference waveforms, and math waveforms

Ordering information

Models

Product Options Supported instruments Bandwidth available
New instrument order option 5-IMDA 5 Series MSO (MSO56, MSO58)
  • 350 MHz

  • 500 MHz

  • 1 GHz

  • 2 GHz

Product upgrade option SUP5-IMDA
Floating license SUP5-IMDA-FL
Product Options6Supported instruments Bandwidth available
New instrument order option 5-IMDA-DQ0 5 Series MSO (MSO56, MSO58)
  • 350 MHz

  • 500 MHz

  • 1 GHz

  • 2 GHz

Product upgrade option SUP5-IMDA-DQ0
Floating license SUP5-IMDA-DQ0-FL
Product Options6Supported instruments Bandwidth available
New instrument order option 5-IMDA-MECH 5 Series MSO (MSO56, MSO58)
  • 350 MHz

  • 500 MHz

  • 1 GHz

  • 2 GHz

Product upgrade option SUP5-IMDA-MECH
Floating license SUP5-IMDA-MECH-FL
Product Options Supported instruments Bandwidth available
New instrument order option 6-IMDA 6 Series B MSO (MSO66B, MSO68B)
  • 1 GHz
  • 2.5 GHz
  • 4 GHz
  • 6 GHz
  • 8 GHz
  • 10 GHz
Product upgrade option SUP6B-IMDA
Floating license SUP6B-IMDA-FL
Product Options6Supported instruments Bandwidth available
New instrument order option 6-IMDA-DQ0 6 Series B MSO (MSO66B, MSO68B)
  • 1 GHz
  • 2.5 GHz
  • 4 GHz
  • 6 GHz
  • 8 GHz
  • 10 GHz
Product upgrade option SUP6B-IMDA-DQ0
Floating license SUP6B-IMDA-DQ0-FL
Product Options6Supported instruments Bandwidth available
New instrument order option 6-IMDA-MECH 6 Series B MSO (MSO66B, MSO68B)
  • 1 GHz
  • 2.5 GHz
  • 4 GHz
  • 6 GHz
  • 8 GHz
  • 10 GHz
Product upgrade option SUP6B-IMDA-MECH
Floating license SUP6B-IMDA-MECH-FL

Software bundles

Supported instrumentsBundle optionsDescription
5 Series MSO5-PRO-POWER-1Y1 Year License Pro Power Bundle for 5 Series MSO
5-ULTIMATE-1YPerpetual License Pro Power Bundle for 5 Series MSO
5-ULTIMATE-1Y1 Year License Ultimate Bundle for 5 Series MSO
5-ULTIMATE-PERPerpetual License Ultimate Bundle for 5 Series MSO
6 Series MSO6-PRO-POWER-1Y1 Year License Pro Power Bundle for 6 Series MSO
6-PRO-POWER-PERPerpetual License Pro Power Bundle for 6 Series MSO
6-ULTIMATE-1Y1 Year License Ultimate Bundle for 6 Series MSO
6-ULTIMATE-PERPerpetual License Ultimate Bundle for 6 Series MSO

Recommended probes

Probe model Description Quantity
TCP0030A Current Probes 3 for 3V3I wiring7
THDP0200 or TMDP0200 High Voltage Differential Probes 3 for 3V3I wiring 7